INSTALLATION • In the technical facility nearby the boiler at the filtering system output (plan a by-pass). • Single-phase electric power supply 230V • In special cases: exchanger supplied from a geothermal or heat pump. • The exchanger must be sized taking into account the heating needs of the pool, the specifications of the exchangers with primary at 45°C or 60°C (see specifications table) and the power of the geothermal. For correct operation of the geothermal we recommend installing a buffer tank as shown in the diagram below. WEIGHT Name Uranus 35 Uranus 70 Uranus 120 Uranus 240 Product Weight (kg) 14kg 29kg 15kg 30kg 17kg 31kg 31kg 50kg DIMENSIONS (MM) UNEQUIPPED MODEL Model URANUS 35-70-120 URANUS 240 Lht 255 407 L2 140 200 L3 50 60 Hht 380 500 H1 339 429 H2 41 75 H3 298 357 DIMENSIONS (MM) PLUS MODEL Model URANUS 35-70-120 URANUS 240 A 758 840 B 334 347 C 415 480 D 116 137 E 414 494 F 250 250 G 200 450 H 127 148 I 50 60 DISCHARGE SUCTION Filter Pump Water treatment By-pass Uranus To radiators Pump Filter Uranus Expansion vessel To other circuits Geothermal heating By-pass Water treatment To horizontal and vertical heating panels DISCHARGE SUCTION A D E B F C G H I H2 H1 H3 Hht Lht L2 L3 HEATING AND COOLING 299