Page 29

LK Armatur - Produktkatalog 2014 ENG

ErP ready 2015 Loading Units | LK 816 ThermoKit E Eco 29 LK 816 ThermoKit E Eco Technical Data Voltage 230 VAC 50/60 Hz Primary voltage, adapter 100-240 VAC 50/60 Hz Secondary voltage, adapter 24 VDC 250 mA Power consumption 10-180 W depending on pump speed, LK SmartComfort CT, 3 VA Max. boiler efficiency Dependent on circulating pump Return temperature 5°C-99°C, adjustable Working temperature Min. +5°C/Max. +95°C Ambient temp. Min. +5°C/Max. +40°C Max. working pressure 1.0 MPa (10 bar) Angle of rotation 90° Torque 5 Nm Max. flow Dependent on circulating pump Media Water - Glycol mixture max. 50% Thread standard Rp - female thread Circulating pumps Grundfos UPML 25-95 180, Grundfos UPMXL 32-105 180 Grundfos Magna 32-80 180 Operation time 140 sec. Protection class IP 40 Material, valve body Brass EN 12165 CW617N Material, insulation Expanded Polypropylene EPP LK 816 ThermoKit E Eco is a loading group for heating applications with solid fuel boilers and storage tanks. The loading group is intended to ensure a high return temperature as well as an optimal temperature stratification in the storage tank, thus increasing the efficiency of the system. Tarring and condensation are prevented which prolongs boiler life. LK 816 ThermoKit E Eco is a unit consisting of a lowenergy circulating pump, that fulfills the requirements of ErP 2015, an LK 840 ThermoMix mixing valve, an LK 100 SmartComfort CT controller with adjustment of the lowest return temperature 5°C-99°C and three ball valves to simplify installation and maintenance. Articles number 181578 and 181579 are delivered with an insulation for the mixing valve. LK 816 ThermoKit E Eco is installed in the return circuit between the solid fuel boiler and the storage tank. The group should be mounted with the drive-shaft of the circulating pump in a horizontal position. The loading group is reversible and can easily be adapted for mounting to the right or left of the boiler. The loading group normally requires no maintenance. The installation should be checked regularly. Thanks to the three ball valves any part can be changed without draining the system, should the need for servicing arise. The function of the loading unit during the different phases of heating: 1. Heat up phase The water circulates between boiler and loading group while the temperature of the boiler is rising. 2. Loading phase The mixing valve starts to open and allows return water from the storage tank to be mixed with supply water before it returns to the boiler. The return temperature to the boiler is kept constant. 3. End phase The mixing valve is fully open towards the storage tank. This results in an optimal transfer of heat from the boiler and the storage tank is filled with supply water. When the boiler has cooled the electronic controller prevents re circulation from storage tank to boiler. 4. Self-circulation In case of power failure or pump breakdown the electronic controller can be manaully operated and the storage tank is loaded through self-circulation.


LK Armatur - Produktkatalog 2014 ENG
To see the actual publication please follow the link above